job_no: 2627
job_name: Airey Park — Strathfield / Homebush West
site_address: Lot 1 in DP 126151 Fraser Street, Homebush West NSW 2140
end_client: Geoscape (per pavement spec) / Strathfield Council park
hc_name: TBD (RFQ not yet supplied; Rocky to confirm)
designer_structural: Capital Engineering Consultants (Parramatta)
designer_pavement: Stellen Consulting (Manly)
architect: NDZ Architects
drawing_set: STR25020 rev D — "Issued for Review" 27.11.2025
spec_pavement: P171342-SP-001-0 rev 0 — "Issued for tender" 11.07.2025
created: 2026-05-08
authored_by: claude-code-orchestrator
---

# 2627 — Airey Park Homebush West

## Quick reference

- **Site:** Lot 1 DP 126151 Fraser Street, Homebush West NSW 2140 (also called "Airey Park" / "Strathfield Parks")
- **Postcode:** 2140 (Sydney inner west, inland metropolitan)
- **Scope category:** Park alterations + additions — function room, storeroom, groundskeeper, terrace, seating terrace, pathway slabs, sandstone retaining wall
- **Drawings (rev D):** S000 general notes, S50 part site plan, S51 seating terrace plan + sections + details, S100 footing plan, S200 ground floor slab plan, plus more sheets pending
- **Pavement spec (rev 0):** P171342 — concrete pavement specification covering materials, equipment, formwork, reinforcement placing, joints, curing, adverse weather, testing, tolerances

## LFCS scope (FRP — formwork + reinforcement-placement + concrete place-finish + curing)

To be confirmed during Phase 3 worker take-off. Provisional from drawings rev D:
- Strip footings SF1 (450 wide × 500 deep) + SF2 (300 × 500)
- Pad footings (sizes per S100)
- Drop edge beams DEB1 (1200 max deep, per S200 detail)
- 150mm slab on ground (internal areas) — SL82 mesh T&B, A1 cover 30/30/30
- 125mm pathway slab (external areas) — SL82 mesh top, A1 cover 40/40/40
- Seating terrace concrete elements per S51 (footings, beams, seating, nosing, steps)
- Joints: sawn control joints (max 4m, 24h saw-cut window), keyed construction joints (max 10m), expansion joints (max 20m)
- Curing: polythene + hessian per pavement spec §10

Scope items NOT in LFCS scope (per Standard Exclusions Library):
- 190mm block walls + brick walls — masonry sub
- Sandstone block retaining wall (S51 detail) — masonry / specialist sub
- Earthworks, sub-base, blinding placement — by HC/earthworks sub
- Concrete supply, reo supply, plant — by HC

## Worker input whitelist (read freely)

Worker reads ONLY these paths from the inbound folder:

- `C:\Users\mclou\lfcs-inbound-artefacts\2627\STR25020 - 2025.12.01.pdf` — Capital Engineering Consultants structural drawings rev D
- `C:\Users\mclou\lfcs-inbound-artefacts\2627\P171342 -SP-001-0 (Pavement).pdf` — Stellen Consulting pavement spec rev 0

Any other file in `C:\Users\mclou\lfcs-inbound-artefacts\2627\` is excluded from worker view; do not enumerate, glob, or pattern-search the inbound folder. Read these two paths directly.

## Posture

- Confidentiality: standard (no agent metadata external; L1 + L2 sanitisation gated on Rocky-typed "send")
- Pricing posture: defensible-for-variations (default per `standing-context.md` §7)
- BoQ format: TBD — likely both lump-sum-letter and BoQ-response (Rocky to confirm)

## Read order for any agent picking this up

1. This file
2. `_Internal/orchestrator-sessions/session-80b1f893-d887-4130-b96f-dd48d5450edd-2627.md` — current session log
3. `_Internal/assumptions-log-2627.md` — auto-decided + flagged intake assumptions
4. `_Internal/exclusions/exclusions-2627.md` — Standard exclusions skeleton + bid-specific carve-outs
5. The two whitelisted PDFs above